Product Code: INDM-005
The Beamex MC6-T combines a state-of-the-art temperature dry block with built-in multifunction process calibrator and communicator technology. It offers versatility that no other temperature calibrator can match, providing calibration capabilities for temperature, pressure, and various electrical signals as well as a multi-bus communicator for fieldbus instruments.
The MC6-T provides superior metrological performance and accuracy for temperature and electrical calibrations. The active multizone (triple/dual) temperature control technology ensures an excellent temperature gradient. Each MC6-T is delivered with a traceable, accredited calibration certificate as standard as proof of its accuracy.
The MC6-T uses advanced, patented methods for following stability, ensuring that only stable temperature readings are used even in demanding industrial environments or with fluctuating mains voltage. It also includes several patented safety features.
The MC6-T offers versatility that no other temperature calibrator can match, providing calibration capabilities for temperature, electrical signals, and even pressure. The MC6-T150 and MC6-T660 provide temperature range from -30 to 660 ⁰C (-22 to 1220 ⁰F)and can perform fully automatic calibrations. Most measurement functions can be used with the rechargeable battery without mains voltage connected.
The MC6-T contains a multi-bus field communicator for HART, FOUNDATION Fieldbus, and Profibus PA protocols to calibrate, configure, and trim your smart instruments. All three protocols can be enabled simultaneously.
The MC6-T is a documenting calibrator that communicates with Beamex calibration management software, enabling a fully digitalized calibration process.
Temperature generation
Pressure measurement (internal barometric and external pressure modules)
Voltage measurement (±1 V and −1…60 VDC)
Current measurement (±100 mA) (internal or external supply)
Frequency measurement (0…50 kHz)
Pulse counting (0…10 Mpulse)
Switch state sensing (dry/wet switch)
Built-in 24 VDC loop supply (low impedance, HART impedance or FF/PA impedance)
Voltage generation ( ±1 V and −3…24 VDC)
Current generation (0…55 mA) (active/passive, i.e. Internal or external supply)
Resistance measurement, two simultaneous channels (0…4 kΩ)
Resistance simulation (0…4 kΩ)
RTD measurement, two simultaneous channels
RTD simulation
TC measurement, two simultaneous channels (universal connector/mini-plug)
TC simulation
Frequency generation (0…50 kHz)
Pulse queue generation (0…10 Mpulse)
HART communicator
FOUNDATION Fieldbus communicator
Profibus PA communicator
| FEATURE | VALUE |
|---|---|
| Dimensions | 322 mm x 180 mm x 298 mm (12,68″ x 7,09″ x 11,73″) |
| Weight | MC6-T150: 9.4 kg (20.7 lbs) MC6-T660: 8.6 kg (18.96 lbs) |
| Display | 5.7” Diagonal 640 x 480 TFT LCD Module |
| Touch Panel | 5-wire resistive touch screen |
| Keyboard | Membrane keyboard |
| Backlight | LED backlight, adjustable brightness |
| Power requirements | 230 V ±10%, 50/60 Hz, 380 W (MC6-T150, 1560 W (MC6-T660) 115 V ±10%, 50/60 Hz, 380 W (MC6-T150), 1560 W (MC6-T660) |
| Fuse size (MC6-T660) | 230 V: T 8A 250V / 115 V: T 16A 250V |
| Fuse size (MC6-T150) | 230 V: T 3.15A 250V / 115 V: T 3.15A 250V |
| Max. input voltage | 30 V AC, 60 V DC |
| Operating temperature | 0 … 45 °C (32 … 113 °F) |
| Operating humidity | 0 … 90% R.H. non condensing |
| Storage temperature | -20 … 60 °C (-4 … 140 °F) |
| Computer interface | USB |
| Calibration certificate | Accredited calibration certificate |
| Warmup time | Specifications valid after a 5 minute warmup period |
| Battery type | Rechargeable lithium-ion polymer, 4300 mAh, 11.1 V |
| Charging time | Approximately 4 hours |
| Battery operation time | 10 … 16 hours |
| Battery operated functions | All functions except temperature control and R3 measurement |
| Safety | Directive 2014/35/EU, EN 61010-1:2010 + A1:2019 + AC:2019-04 |
| EMC | Directive 2014/30/EU, EN IEC 61326-1:2021 |
| RoHS compliance | RoHS II Directive 2011/65/EU, EN IEC 63000:2018 |
| Drop | EN 61010-1:2013 |
| Warranty | Warranty 3 years, 1 year for battery pack. Warranty extension programs available. |
Be the first to write a review
We are retiring PICOPC Products MNHO-073, MNHO-048 and MNHO-043 and they have reached EOL (End Of Life) as we are introducing new products with better technology. We would recommend you to look into MNHO-095. For Untangle, pfSense, OPNsense, Windows 11, Proxmox VE etc. we recommend MNHO-095 whereas for Sophos, Kerio Control and Endian, we would recommend MNHO-069. (A complete list of supported OS can be found in each product's listing)