The Fluke 726 Precision Multifunction Process Calibrator is a precise, powerful, and easy-to-use field calibrator designed specifically for process industries. It offers broad workload coverage, strong calibration capability, and high accuracy required by process professionals. The device measures and sources almost all process parameters, allowing users to calibrate a wide range of instruments. It can be used to test sensors and valves and to test and calibrate transmitters. The Fluke 726 can also interpret calibration results without requiring a calculator and store measurement data for later analysis.
The calibrator measures volts, mA, pressure, RTDs, thermocouples, frequency, and resistance, making it suitable for testing sensors and transmitters. It can also source and simulate volts, mA, thermocouples, RTDs, and frequency to calibrate transmitters. When paired with any of the 50 Fluke 750P Series Pressure Modules, the device can measure and source pressure to test and calibrate pressure transmitters and other pressure devices.
The Fluke 726 can source mA while simultaneously measuring pressure, which is useful for conducting valve and I/P tests. It also enables enhanced flowmeter testing through a frequency totalizer and frequency pulse train source mode.
The calibrator includes several built-in features that improve usability in different measurement situations. It can store frequently used test setups and allows users to program custom RTD probe calibration constants for improved temperature measurement accuracy. The integrated voltage input protection design enhances reliability during operation.
The instrument uses two separate channels, allowing users to measure, source, or view process signals simultaneously. It also features a backlit display, which improves visibility when working in low-light environments. Additionally, the device is backed by a standard 3-year warranty.
The Fluke 726 can capture the set, reset, and deadband of a pressure switch using its integrated switch test feature. It can also calculate transmitter error percentage, allowing users to interpret calibration results without using a calculator. The auto-step and auto-ramp features support fast linearity testing. During testing, the calibrator can power a transmitter using a 24 V loop supply while simultaneously measuring mA.
The package includes the Fluke 726 Precision Multifunction Process Calibrator, one set of AC72 alligator clips, one pair of stackable test leads, one pair of TL75 test leads, a traceable calibration report and data, a Quick Reference Guide, and a 3-year warranty.
| Category | Parameter | Range / Type | Accuracy / Specification |
|---|---|---|---|
| Measurement Accuracy | Voltage DC | 30.000 V | 0.01% + 2 mV (upper display) |
| Voltage DC | 20.000 V | 0.01% + 2 mV (lower display) | |
| Voltage DC | 90.00 mV | 0.01% + 10 μV | |
| Voltage DC | -10.00 mV to 75.00 mV | 0.025% + 1 count (via TC connector) | |
| Current DC | 24.000 mA | 0.01% + 2 mA | |
| Resistance | 0.0 to 4000.0 Ω | ± 0.015% | |
| Frequency | 2.0 to 1000.0 CPM | 0.05% + 0.1 cpm | |
| Frequency | 1.0 to 1000.0 Hz | 0.05% + 0.1 Hz | |
| Frequency | 1.00 to 15.00 kHz | 0.05% + 0.01 kHz | |
| Sensitivity | 1 V peak-to-peak minimum | ||
| Pressure | Accuracy from 0.025% of range using any of (50) 750P pressure modules | ||
| Source Accuracy | Voltage DC | 100.00 mV | 0.01% + 10 μV |
| Voltage DC | 20.000 V | 0.01% + 2 mV | |
| Voltage DC | -10.00 mV to 75.00 mV | 0.025% + 1 count (via TC connector) | |
| Current DC (Source) | 24.000 mA | 0.01% + 2 μA | |
| Current DC (Simulate) | 24.000 mA | 0.01% + 2 μA | |
| Resistance | 5 to 400 Ω | 0.015% + 0.1 Ω, excitation current 0.1 to 0.5 mA | |
| Resistance | 5 to 400 Ω | 0.015% + 0.05 Ω, excitation current 0.5 to 3 mA | |
| Resistance | 400 to 1500 Ω | 0.015% + 0.5 Ω, excitation current 0.05 to 0.8 mA | |
| Resistance | 1500 to 4000 Ω | 0.015% + 0.5 Ω, excitation current 0.05 to 0.4 mA | |
| Frequency | 2.0 to 1000.0 CPM | 0.05% | |
| Frequency | 1.0 to 1000.0 Hz | 0.05% | |
| Frequency | 1.0 to 10.0 kHz | 0.25% | |
| Frequency | 10.0 to 15.0 kHz | 0.5% | |
| Waveform | 5 V p-p squarewave, -0.1 V offset | ||
| RTD Accuracy | Cu10 | 1.8°C | |
| NI-120 | 0.15°C | ||
| PT-100 (385) | 0.45°C | ||
| PT-100 (392) | 0.35°C | ||
| PT-100 (391-JIS) | 0.35°C | ||
| PT-200 (385) | 0.95°C | ||
| PT-500 (385) | 0.55°C | ||
| PT-1000 (385) | 0.35°C | ||
| RTD Resolution | Temperature | 0.01°C (0.01°F) | |
| Thermocouple Accuracy | Cu10.01 C | 0.1°C (0.1°F) | |
| J | 0.4°C | ||
| K | 0.5°C | ||
| T | 0.4°C | ||
| E | 0.4°C | ||
| R | 1.4°C | ||
| S | 1.4°C | ||
| B | 1.4°C | ||
| L | 0.45°C | ||
| U | 0.45°C | ||
| N | 0.6°C | ||
| XK | 0.4°C | ||
| BP | 1.1°C | ||
| TC Resolution | Thermocouples | J, K, T, E, L, N, U | 0.1°C, 0.1°F |
| Thermocouples | B, R, S | 1°C, 1°F | |
| Ramp Functions | Source Functions | Voltage, current, resistance, frequency, temperature | |
| Ramp Types | Slow ramp, Fast ramp, 25% step-ramp | ||
| Loop Power | Voltage | 24 V | |
| Accuracy | 10% | ||
| Maximum Current | 22 mA, short circuit protected | ||
| Step Functions | Source Functions | Voltage, current, resistance, frequency, temperature | |
| Steps | 25% of range, 100% of range | ||
| Environmental | Operating Temperature | -10°C to +55°C | |
| Storage Temperature | -20°C to +71°C | ||
| Operating Altitude | 3000 m | ||
| Safety | Agency Approvals | EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992 | |
| Mechanical | Size | 200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in) | |
| Weight | 650 g (23 oz) | ||
| Power | Batteries | 4 AA alkaline batteries | |
| Battery Replacement | Separate battery compartment, accessible without breaking calibration seal | ||
| Connections | Side Port Connections | Pressure module connector, also used for remote real-time programming |
No Attachments Found!
Be the first to write a review
We are retiring PICOPC Products MNHO-073, MNHO-048 and MNHO-043 and they have reached EOL (End Of Life) as we are introducing new products with better technology. We would recommend you to look into MNHO-095. For Untangle, pfSense, OPNsense, Windows 11, Proxmox VE etc. we recommend MNHO-095 whereas for Sophos, Kerio Control and Endian, we would recommend MNHO-069. (A complete list of supported OS can be found in each product's listing)